The diver flange is used as a feed-through for breathing gases and the associated electrical lines through the pressure wall of the TBM via one DN100 flange connection per diver. The application is possible up to a pressure difference of up to 10 bar.
Technical data:
Diameter: 76 mm
Length: 300 mm
Material: Stainless steel 1.4571 / 1. 4404 / MS 58 nickel-plated
Differential pressure : 10 Bar
Fastening: Clamp connection, sealing via a lip seal
Passage for breathing gas: 2 x diameter 10 mm, ¼” internal thread, pressure resistant up to 300 bar
Passage for communication: pressure-resistant screw connection 10 bar, thread 16 x 1.5 mm, maximum cable diameter 9 mm